Cautionary statements, Network access requirements – Brocade Mobility RFS9510 Controller Installation Guide User Manual
Page 7

Brocade Mobility RFS9510 Controller Installation Guide
3
53-1002918-01
Getting started
1
Network access requirements
•
TCP 22—used for SSH (protocol 2 only) access for occasional administrative tasks.
Cautionary statements
CAUTION
There are no user-serviceable components inside the Mobility RFS9510 Controller Opening the 
chassis will void the warranty.
CAUTION
BIOS settings on the Mobility RFS9510 Controller should not be changed. Changing any settings 
in the BIOS will void all warranty on the controller.
CAUTION
To prevent the controller from overheating, never install in an enclosed area not properly 
ventilated or cooled. For proper airflow, keep the front and back sides of the controller clear of 
obstructions and away from the exhaust of other equipment.
CAUTION
The recommended / ambient operating temperature is 10ºC - 35ºC (50ºF - 95ºF). Installation in a 
closed or multi-rack assembly may raise the immediate ambient temperature above the average 
room temperature. Exercise due caution.
CAUTION
Ensure the electrical circuit through which the controller is powered can safely accommodate a 
750 Watt power supply.
CAUTION
Brocade highly recommends you connect the Mobility RFS9510 Controller to an Uninterruptible 
Power Supply (UPS). There are instances in which the system software could become corrupt and 
un-recoverable in the event of power loss, for example, during a system upgrade, database 
backup or database restore operation.