On off, Factory default settings, Volume strobe siren – STI 7555 User Manual
Page 5

- 5 -
1
0 0 0 0 0
BUZZ
2
1 0 0 0 0
SLOW ON/OFF
3
0 1 0 0 0
SLOW SIREN
4
1 1 0 0 0
3 BEEP/PAUSE/REPEAT
5
0 0 1 0 0
UFO FAST
6
1 0 1 0 0
FAST SIREN
7
0 1 1 0 0
#5 FAST
8
1 1 1 0 0
#2 MEDIUM
9
0 0 0 1 0
#5 MEDIUM
10
1 0 0 1 0
SWOOP MEDIUM
11
0 1 0 1 0
#3 MEDIUM
12
1 1 0 1 0
BUZZ TONE
13
0 0 1 1 0
STEADY FAST
14
1 0 1 1 0
SWOOP SLOW
15
0 1 1 1 0
CONTINUOUS
16
1 1 1 1 0
FAST REPEAT
17
0 0 0 01
STANDARD ALARM
18
1 0 0 0 1
#3 FAST
19
0 1 0 0 1
#5 SLOW
20
1 1 0 0 1
FAST BEEP
21
0 0 1 0 1
SOUND A
22
1 0 1 0 1
SOUND B
23
0 1 1 0 1
SOUND C
24
1 1 1 0 1
SOUND D
25
0 0 0 1 1
SOUND D LOUD
26
1 0 0 1 1
SOUND E
27
0 1 0 1 1
SOUND F
28
1 1 0 1 1
SOUND G
29
0 0 1 1 1
SOUND H
30
1 0 1 1 1
#4 LOW
31
0 1 1 1 1
SOUND K
32
1 1 1 1 1
CONTINUOUS FAST
1
ALARM TIMING
VOLUME
STROBE TIMING
ON
OFF
1
2
3
4
5
0
15 seconds
1
1
1
1
High
30 seconds
1
0
1
0
1
60 seconds
0
1
0
1
Low
Continuous
0
0
0
0
0
1 = ON
0 = OFF
STEP 3 - ALARM TONES - S1
STEP 4 - ALARM TIMING AND VOLUME - S2
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
O
O
1 2 3 4 5
1 2 3 4 5
ALARM
TIMING
1 2
3 4
5
VOLUME
STROBE
SIREN
*
Factory default settings
*
*
STEP 2 - ELECTRONIC SETUP -
SELECT ALARM TONE AND TIMING SEQUENCE
NOTE:
Select-Alert must be on a flat surface and lens must be
installed or the tamper switch will trigger the alarm.
NOTE
Sound may be disabled by clipping wires to
the siren. THIS WILL VOID ALL WARRANTIES.
Remove two screws on circuit board; leave
enough length of wire to possibly reattach in
the future. Then insulate wires to prevent
shorting to electronic components.
O
O
WIRES TO SIREN