CONTROL MODE

Control Mode provides access to the Loudspeaker

Amplifier’s internal DSP and allows you to control its

settings. You can enter Control Mode by clicking on the

Control button at the top of the main workspace, or from

within any loudspeaker’s Properties window. Any or all

of the Control functions can be restricted to authorized

operators who have password access; more information

on password authorization can be found in the Supervise

Mode section of this manual.

When you enter Control mode in the main workspace, the

directory tree on the left remains the same.

However, notice that the icons themselves have changed.

The CobraNet Rx and Tx arrows are gone. On the left

side Wink and Power buttons have been added. On the

right side, a Mute button is labeled with a driver symbol.

Below it is a Signal Present indicator.

Double-click an array icon to open its Properties window in Control mode. Notice that the left hand section of the Control Mode Properties

window is the same as in Connect mode.

Turns “Wink” Light ON & OFF

Status Indicator

Name

Mute Button

Signal Present indicator

Toggles Power from On

to Standby