beautypg.com

Technical specification, Limits of application – Stuart Turner Boostamatic2/T12-2 User Manual

Page 4

background image

- 4 -

Cont ...

Notes:
Max. viscosity: 9.5 centistokes (Redwood No 1 scale).
Max. ambient air temp: 40°C
*

With footvalve fitted.

**

Max working pressure is the maximum pressure that can be applied to the pump

internal casing under any installation conditions.

***

Maximum permissible liquid temperature 65°C.

**** The supply voltage must not exceed ±10% of the above listed

voltage. eg. 230 ±10% Failure to adhere will damage the unit.

TECHNICAL SPECIFICATION

Note: For information on other voltages/frequencies which are not shown, consult any

supplementary instruction sheet supplied, or the rating label attached to the

pump.

Stuart Turner reserve the right to amend the specification in line with its policy of

continuous development of its products.

LIMITS OF APPLICATION

Model

Supply

(Note ****)

Max.

Liquid

Temp.

o

C

(Note ***)

Min.

Liquid

Temp.

o

C

Max.

Suction

Lift (m)

(Note *)

Max. No.

Starts/h

Cut in

Pressure

(bar)

Cut Out

Flow

(l/min)

Max.

Working

Pressure

kPa (bar)

(Note **)

Max.

Inlet

Head

(m)

Max.

Head

(m)

(pump

closed

valve)

4000

230/1/50

65

4

4.6

60

1.4

1.0

600 (6)

13

29.5

6000

230/1/50

65

4

4.6

60

1.4

1.0

600 (6)

13

41.0

K7-2

230/1/50

65

4

4.6

60

0.8

1.0

600 (6)

8

13.5

L5-4S

230/1/50

65

4

4.6

60

1.8

1.0

700 (7)

13

45.0

L7-4S

230/1/50

65

4

4.6

60

1.8

1.0

700 (7)

13

47.0

T6-2

230/1/50

65

4

4.6

60

1.8

1.0

400 (4)

10

31.0

T12-2

230/1/50

65

4

4.6

60

1.8

1.0

400 (4)

8

31.5

Model

Supply

Max. Watts
Consumed

Nominal

Watts

Output

(Motor)

Full

Load

Current
(AMPS)

Enc.

Rating

Duty

Rating

Dims (mm)

Gross

Weight

(packed)

kg

No. of

Pump

Stages

L

W

H

4000

230/1/50

360

120

1.6

IP44

Continuous (S1) @

4.5 l/min and above

232

132

292

7.15

1

6000

230/1/50

550

300

2.5

IP44

Continuous (S1) @

4.5 l/min and above

232

132

292

7.75

1

K7-2

230/1/50

450

360

2.0

IP44

Continuous (S1)

242

159

302

8.9

1

L5-4S

230/1/50

950

600

4.2

IP44

Continuous (S1)

401

288

355

10.85

4

L7-4S

230/1/50

1055

760

4.9

IP44

Continuous (S1)

425

288

355

10.35

4

T6-2

230/1/50

920

530

4.1

IP44

Continuous (S1)

326

284

353

10.75

2

T12-2

230/1/50

1150

800

5.3

IP44

Continuous (S1)

350

284

353

10.25

2