beautypg.com

Stuart Turner PH 35 TS FL User Manual

Page 9

background image

- 9 -

Cont ...

2.29

Hot water supply: The pump must be supplied with a dedicated feed direct

from the hot water cylinder or storage tank which should be via a secondary

dedicated tapping (see Fig. 7 for KFL or Fig. 8 for all other models).

Do not connect to the mains.

Fig. 7

45°

Essex flange
28 mm

Off expansion
pipe, off-set
45°, 28 mm
pipework

Off vertical
expansion
pipe, 28 mm
pipework

Fig. 8

Off expansion
pipe with rising
28 mm offset
reducing to
22 mm pipework
to pump and
expansion pipe.

Off expansion
pipe with rising
22 mm offset
and 22 mm
pipework to
pump.

Off vertical
expansion pipe
with 22 mm
pipework to
pump.

Factory installed G ¾
secondary tapping
with 22 mm pipework
to pump.

or

Side mounted Stuart
flange side entry (SE)
with 22 mm pipework
to pump

G 1 Stuart flange top
entry (TE) (Part No.
27800) with 22 mm
pipework to pump.

This manual is related to the following products: