beautypg.com

Stuart Turner Jet Pump 45 B User Manual

Page 8

background image

- 8 -

Cont ...

2.26

Self Priming: Jet 55-45 B and 80-45 B pumps are capable of self priming the

suction hose assembly, providing a footvalve and strainer (not supplied) is

always used for this type of installation. The Jet pump can be used in a suction

lift installation providing the height of lift is no greater than maximum permitted

(Fig.

5).

2.27

Footvalve/strainer: It is important that the optional footvalve and strainer is

always used for suction lift installations.

2.28

Suction pipe: Lay the suction piping over the shortest possible distance and

ensure there is a constant rise from the water source to the pump. Any high

spots will cause air pockets to form reducing system efficiency. The suction hose

must be a minimum of 25 mm to ensure the pump is not starved of water and

must be reinforced to prevent it collapsing.

2.29

Connections: Ensure all joints in suction pipework are completely airtight.

Failure to comply will result in loss of prime.

2.30

Position: The intake of the footvalve/strainer should be positioned so that it

cannot be blocked with debris or silt that are frequently found in the bottom of

sumps and wells.

2

LOCATION - PUMP MOUNTED ABOVE WATER SOURCE (SUCTION LIFT

INSTALLATION)

Fig. 5

Ensure inlet area
around strainer is
free from debris

Max. suction lift 5 m

0.5 m min