If an extension cord is necessary a cord of the proper type and rating must be used .

In general for 230 volt pumps on distances up to 40 metres (inclusive of original cord

length) the same specification cord as fitted to the pump can be used . For distances

above 40 metres a larger cord size may be required due to voltage drop and advice must

be obtained based upon installation details .

Any connectors or junction boxes must be specifically suited for outdoor use and

installed in accordance with manufacturers instructions .

Any cable routed underground must be protected to local standards .

NOISE

The equivalent continuous A-weighted sound pressure level at a distance of 1 metre

from the pumpset does not exceed 70 dB(A) .

COMMISSIONING

WARNING:

The pump chamber must be full of water at all times . Damage will

result if pump runs dry .

1 . The pump must be fully submerged before starting . Take care when submerging the

pump to ensure all air is purged from the casing . This is done by slowly submerging

the pump and gently agitating whilst doing so . This will enable any trapped air

pockets to be released .

2 . Turn on the electrical supply and water movement should be immediately evident

from pump outlet . If it is not, repeat step 1 .

For Further Technical Support

Note: When pumps are installed in another manufacturers original equipment, please

contact the manufacturer for advice .

Phone the Stuart Turner Pump Assist team on 0844 98 000 97 . Our staff are trained to

help and advise you over the phone or arrange for a service engineer to call .

Supply Cord Extension

The pumps are fitted with a supply cord suitable for outdoor and underwater use . The

cord specification is as follows:-

Pump Type

Cord Type

Cord Length (m)

All Models

HO5RN-F3 G 0 .75 mm²

10

Cont . . .