Supply Cord Replacement
The power supply cord of this pump cannot be replaced . If the cord is damaged, the
pump should be scrapped .
Electrical Connection
The motor is provided with a factory fitted supply cord and plug . This must be connected
to the mains supply via a 13 Amp double pole switched, socket outlet in compliance with
BS 1363-2 .
The socket outlet should be mounted in an easily accessible position and should be
labelled if confusion is possible, to allow easy identification of the pump isolating switch .
Wiring
The moulded plug fitted to this appliance is not waterproof - keep dry .
The supply cord is factory fitted with a moulded plug incorporating a fuse, the value of
which is indicated on the pin face of the plug . Should the fuse need to be replaced, an
ASTA approved BS 1362 fuse must be used of the same rating, marked thus,
. If the
fuse cover is detachable, never use the plug with the cover omitted . If a replacement fuse
cover is required, ensure it is of the same colour as that visible on the pin face of the plug
(i .e . red or orange) .
If the plug supplied is not suitable for your socket outlet, it should be cut off and
destroyed .
WARNING: A plug with bared flexible cords is hazardous if engaged in a
live socket outlet .
The end of the flexible cord should be suitably prepared and correct plug fitted, as
follows:
The wires in this mains lead (supply cord) are coloured in accordance with the following
code:
Green & Yellow: Earth
Blue:
Neutral
Brown: Live
As these colours may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the
plug which is marked with the letter ‘E’ or by the earth symbol or coloured green or
green and yellow .
The wire which is coloured blue must be connected to the terminal which is marked with
the letter ‘N’ or coloured black or blue .
The wire which is coloured brown must be connected to the terminal which is marked
with the letter ‘L’ or coloured brown or red .
Fuses
The following fuse size should be used with the appropriate pump .
Model
Fuse Size (AMPS)
All Models
13