beautypg.com

Stuart Turner CH 4-30 B User Manual

Page 12

background image

- 12 -

3.23

Supply Cord Replacement:

The supply cord and internal wiring within the terminal box are
routed and secured to ensure compliance with the electrical
standard EN 60335-1. It is essential that prior to any disturbance
of this internal wiring, all cable routing and securing details are
carefully noted to ensure re-assembly to the same factory pattern
is always maintained.

If the supply cord is to be changed or is damaged, it must be replaced with a

special cord assembly available from Stuart Turner or one of their approved

repairers.

On disassembly note the cord retention and routing system. Re-assemble to the

same

pattern.

For information on cable connection consult the wiring diagram and cable gland

fitting

instructions.

3.24

Cable Gland Fitting Instructions:

To enable correct assembly of the cable gland the

‘O’-ring (Fig. 10 item 1) must be placed over the cable

before the clamping insert (Fig. 10 item 2) can be

tightened.

Note: Cable diameter range:- 6.5 mm to 9.5 mm.

3.25

Supply Cord Extension:

The pumps are fitted with a supply cord to the following

specification:-

All models . . . . . . . . . . . . . . . . . HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.

If the supply cord is to be extended, a cord of the same specification should be

used. Any connections or junction boxes used should be specifically suited for

the application and installed in accordance with the manufacturers instructions.

3.21

Wiring Diagram:

Model

Fuse Size (AMPS)

All Models

13

3.22

Fuses: The following fuse size should be used with the appropriate pump:

Fig. 10

2

1

GREEN / YELLOW

BLUE

BROWN

L

M

A

N

N

L

E

N 230 VAC/1PH/50Hz

SUPPLY

RED

CAPACITOR

MOTOR

GREEN / YELLOW (LINK WIRE)

RE

D

YELLOW

RED

BLA

CK

BLACK

FLOWSWITCH
REED (S3)

S3 S3 S2

S2

S1

S1

PRESSURE
SWITCH (S1)

All models

Fig. 9

This manual is related to the following products: