Fig. 2
Grub Screws
(3 off)
Outlet Tower can be swivelled at
this joint line after loosening the
3 equi-spaced grub screws
PRE-INSTALLATION ASSEMBLY
Re-positioning of Pressure Vessel
The pressure vessel can be rotated to alternative positions (Figs. 3 & 4) in the event of
the factory fitted position being unsuitable for a specific installation.
a) Remove pressure vessel by unscrewing anti-clockwise.
b) Using a 2 mm allen key (not supplied), carefully loosen all three retaining grub
screws by two turns (Fig. 2).
c)
Warning - Care must be taken when re-positioning the pressure vessel to
ensure no strain is placed upon the pressure
switch or reed switch cables.
The flow switch assembly can now be carefully
rotated to an alternative position
(Figs. 3 & 4).
d) Ensure all three grub screws are
re-tightened securely to a torque
of 2.2 Nm (1.62 ft lbf).
e) Re-fit the pressure vessel
ensuring the ‘O’-ring seal
is in place.
Motor
Motor
Factory fitted position
U1.4 bar
Area for alternative fitting
positions
Area for alternative fitting positions
Factory fitted position U2.6 bar,
U3.6 bar, U5.0 bar
Fig. 3
Fig. 4