CHANGING COOLANT TYPE

The MCX-2 has a means for easily using different types of coolants. A special feature
is the clearing process which purges coolant from the hoses and pumps prior to
changing the new coolant tank. The MCX-2 must be connected to a battery during this
procedure.

1. Slide the New Coolant Tank to the rear and sit it on the floor.

2. Disconnect the green hose from the tank.

3. Close the valve on one of the Step Adapters and install on the green hose

disconnected from the New Coolant Tank.

4. Close the valve and install the Wand on the long green hose.

5. Press the top of the FILL SYSTEM selector switch to start the pump.

6. Insert the end of the Wand in the fill port on the New Coolant Tank. Open the

valve on the Wand and then open the valve on the Step Adapter. All coolant in
the hoses and pump will be emptied into the New Coolant Tank.

7. Close the valve on the Wand and Step Adapter. Press the bottom of the FILL

SYSTEM selector switch to turn off the pump.

8. Remove the Step Adapter from the green hose and connect a New Coolant

Tank with a different type of coolant.