4 green series communication function expansion, Additional connecting mode (controllers) – Yokogawa Data Acquisition with PID Control CX2000 User Manual
Page 7
![background image](/manuals/360254/7/background.png)
IM CX2000-S30E
5
1.4 Green Series Communication Function Expansion
Additional Connecting Mode (Controllers)
The external controllers kinds, of which parameters CX can auto-read are added as
follows. (The functions that CX supports UT series can be used.)
- Additional connecting kinds: US1000, UT100 series (UT130, UT150, UT152, and
UT155)
The following control modes and alarm kinds can be selected from CX.
US1000
- Control mode:
Single-loop control, Cascade-primary loop control, Cascade secondary-loop control, Cascade
control, Loop control for backup, Loop control with PV switching, Loop control with PV
auto-selector, Loop control with PV-hold function, Dual loop control, Temperature and Humidity
control, Cascade control with two universal inputs, Loop control with PV switching and two
universal inputs, Loop control with PV auto-selector and two universal inputs
- Alarm kinds (number of alarm: 4)
Off, PV high-limit alarm (energize), PV low-limit alarm (energize), Deviation high-limit alarm
(energize) Deviation low-limit alarm (energize), Deviation high-limit alarm (deenergize),
Deviation low-limit alarm (deenergize), Deviation high & low limit alarm (energize), Deviation
within high & low limits alarm (energize), PV high-limit alarm (deenergize), PV low-limit alarm
(deenergize), PV high-limit alarm (energize/hold), PV low-limit alarm (energize/hold)Deviation
high-limit alarm (energize/hold), Deviation low-limit alarm (energize/hold), Deviation high-limit
alarm (deenergize/hold), Deviation low-limit alarm (deenergize/hold), Deviation high & low limit
alarm (energize/hold), Deviation within high & low limits alarm (energize/hold), PV high-limit
alarm (deenergize/hold) , PV low-limit alarm (deenergize/hold), PV change-rate alarm
(energize), PV change-rate alarm (deenergize), Self-diagnosis alarm (energize),
Self-diagnosis alarm (deenergize), FAIL output, SP high-limit, SP low-limit SP-L, Output
high-limit, Output low-limit.
UT100 series
- Control mode: Single loop control
- Alarm kinds (number of alarm: 2)
Off, PV high-limit alarm (energize), PV low-limit alarm (energize), Deviation high-limit alarm
(energize) Deviation low-limit alarm (energize), Deviation high-limit alarm (deenergize),
Deviation low-limit alarm (deenergize), Deviation high & low limit alarm (energize), Deviation
within high & low limits alarm (energize), PV high-limit alarm (deenergize), PV low-limit alarm
(deenergize), PV high-limit alarm (energize/hold), PV low-limit alarm (energize/hold)Deviation
high-limit alarm (energize/hold), Deviation low-limit alarm (energize/hold), Deviation high-limit
alarm (deenergize/hold), Deviation low-limit alarm (deenergize/hold), Deviation high & low
limit alarm (energize/hold), Deviation within high & low limits alarm (energize/hold), PV
high-limit alarm (deenergize/hold) , PV low-limit alarm (deenergize/hold), Self-diagnosis
output, FAIL output, Timer function, Timer function (deenergize), Heater burn out alarm