Flowrate Decimal
The number of decimal points with which the
flowrate is displayed.
Total Decimal
The number of decimal points with which the
total is displayed.
Temperature Offset
This allows a small offset to be programmed to
correct for any offset error in the RTD. For
example, if during "TEST" the temperature was
read at 125.3°C when it was known that the
actual temperature was really 124.8°C, then an
offset of -0.7°C could be programmed to correct
for the error in the RTD.
Pressure Input
Both absolute and gauge pressure systems can
be used with the Model 415.
Atmospheric
Pressure
If a gauge pressure sensor is used, the
atmospheric pressure must be programmed
since this will vary with the altitude of the
installation.
Note that the Absolute Pressure = Atmospheric
Pressure + Gauge Pressure. The atmospheric
pressure will default to 101.325 kPa (14.696
psia) which is the standard value at sea level.