2. SPECIFICATION
General
Display:
Alphanumeric LCD display with
backlighting and 2 lines x 20 characters/line.
Each character 5.5mm high.
Keyboard:
Sealed membrane keyboard with four keys.
Transducer Supply:
8-24VDC field adjustable, 65mA maximum.
Power Requirements:
14 to 28.0 VDC, 300mA typical.
AC mains - Set internally to 95 - 135 VAC
or
190 - 260 VAC.
Operating Temperature:
0 to 55°C.
Facia:
Watertight to IP65 or Nema 3S.
Dimensions:
144mm (5.7") wide x 72mm (2.8") high x
188mm (7.4") deep.
Depth behind Panel:
139mm (5.5") x 67mm (2.6").
Frequency Input
Frequency Range:
Minimum:
0.25Hz on Rate.
0Hz on Total.
Maximum:
10KHz.
Input Circuits:
Will accept most sine logic and proximity
switch inputs (see section 6.1).
K-factor Range:
0.1000 to 999,999.
Non-Linear Correction:
Up to 10 correction points.