Yokogawa 415 Steam and Gas User Manual
Page 17

Steam
Mass
(Rate & Total)
Energy
(Rate & Total)
Temperature & Pressure
Specific Weight & Enthalpy
If any value other than the default display values are selected, they will remain
displayed for 5 seconds, after which the display will automatically revert to the
default values.
Totals are displayed with a maximum of 8 digits, including decimals. For
example, if two decimals are programmed, the maximum total is 999,999.99,
after which the totals roll over to zero and continue counting.
For large flowrates, totals can be integrated at 1/1000 of the flowrate by
programming the Total Units function at x 1000. The units of measure will then
be displayed as follows:
SI Units
Rate
Total
cm/h
kcm
scm/h
kscm
Nm
3
kNm
3
kg/h
tonne
MJ/h
GJ
US Units
Rate
Total
cft/h
kcft
scft/h
kscft
lbs/h
klbs
BTU x 1000/h
MBTU
(Note: k = x 1000, M = x 1,000,000, G = x 1,000,000,000).
The RESET key can be used to reset the totals whenever one of the totals is
displayed. Both totals will be reset at the same time. The RESET switch can be
disabled during calibration to prevent front panel resetting.
Operation 15