Remote rack-mount Converter RCCR31, Model, Suffix and Option Code
Model
Suffix Code
Option
Code
Description
Restrictions
RCCR31
Remote converter for 19´´ rack mounting to be connected to RCCS3
Power supply
-A
-D
90 - 264 V AC
24 V DC
Hazardous Area Approvals
1)
/KS1
/FS1
/ES1
/US1
ATEX associated apparatus for intrinsic safe detector connection for gas group IIC
FM associated apparatus for intrinsic safe detector output
IECEx associated apparatus for intrinsic safe detector output for gas group IIC
INMETRO associated apparatus for intrinsic safe detector output for gas group IIC
with /HP for gas group IIB
with /HP not for gas groups A and B
with /HP for gas group IIB
with /HP for gas group IIB
GOST
1)
/QR1
/QR2
Primary Calibration and Test Confirmation valid in Russia
Primary Calibration and Test Confirmation valid in Kazakhstan
see page 9
see page 9
High Driving Power
/HP
High Driving Power
not for combination with RCCS30 to 34, recom-
mended for combination with RCCS36 to 39,
strongly recommended for combination with
RCCS39/IR, mandatory for combination with
RCCS39/XR
Active Pulse Output
/AP
One active pulse output
not with /NM
NAMUR Switch
/NM
One pulse output acc. EN 60947-5-6 (NAMUR)
not with /AP
Communication
/MB1
Modbus communication protocol for selected parameters and values
not with /AP
Tag Number
/BG
With customer specified tag number on name plate
max. 16 digits
HART Tag Number (Software Tag)
/BT1
With customer specified tag number for HART communication in converter
8 digits for tag, 22 digits for long tag
Gas Measurement
/GA
Gas measurement, special factory adjustments and settings
select affiliated RCCS3 with /GA
Combination with RCCS39/XR
/XR
Special converter adjustment with RCCS39/XR
mandatory for combination with RCCS39/XR
No Combination
/NC
No combination with detector
Customer Presetting
/PS
Presetting sheet with customer data
has to be issued with the order
Concentration Measurement
2)
/CST
/Cxx
Standard concentration measurement
Advanced concentration measurement, details see table „Advanced Concentration
Measurement Options“
Subrack
/SR2
/SR4
Subrack for 2 converter RCCR31 with mounting
Subrack for 4 converter RCCR31 with mounting
Delivery to Korea
/KC
With KC-mark for Korea
Instruction Manuals
/IEn
/IDn
/IFn
Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French
n = 1 to 3 selectable
3)
n = 1 to 3 selectable
3)
n = 1 to 3 selectable
3)
Special order
/Z
Special design must be specification an extra sheet