Yokogawa RotaMASS 3-Series User Manual
Page 73

IM 01R04B08-00E-E 1st edition February 15, 2012 -00
All Rights Reserved. Copyright © 2012, Rota Yokogawa
<10. GENERAL SPECIFICATIONS>
10-3
Remote field-mount Converter RCCF31, Model, Suffix and Option Code
Model
Suffix Code
Option
Code
Description
Restrictions
RCCF31
Remote field-mount converter to be connected to RCCS3;
when ordered without detector combination option /NC must be selected
Power supply
-A
-D
90 - 264 V AC
24 V DC
Indicator direction
H2
N0
With indicator
Without indicator
Cable conduit connection
M
A
M20 x 1.5, female thread with cable glands
ANSI ½´´ NPT, female thread, only cable gland for detector connection
mandatory with /FF1, /FF2
Hazardous Area Approvals
1)
/KF1
/KF2
/FF1
/FF2
/EF1
/EF2
/UF1
/UF2
ATEX Flame proof converter + Intrinsic safe detector output
ATEX Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector
output + 2 active analog outputs + 2 passive pulse outputs + 1 status input
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector
output + 1 passive analog output + 1 passive pulse output
IECEx Flame proof converter + Intrinsic safe detector output
IECEx Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs
INMETRO Flame proof converter + Intrinsic safe detector output
INMETRO Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs
with /HP for gas group IIB
with /HP for gas group IIB
only with cable conduit ´A´; with /HP not for
groups A and B
only with cable conduit ´A´; with /HP not for
groups A and B
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
Custody Transfer Measurement
acc. OIML R 117-1
/Q01
European MID Approval (fluids other than water) (refer to GS 01R04B07-00E)
GOST
1)
/QR1
/QR2
/QR3
Primary Calibration and Test Confirmation valid in Russia
Primary Calibration and Test Confirmation valid in Kazakhstan
Primary Calibration and Test Confirmation valid in Uzbekistan
see page 9
see page 9
see page 9
Communication
/FB
/MB1
Digital communication Foundation Fieldbus protocol (refer to GS 01R04B05-00E)
Modbus communication protocol for selected parameters and values
not with /FB, /Q01, /KF2, /EF2, /UF2, /FF2, /AP
High Driving Power
/HP
High Driving Power
not for combination with RCCS30 to 34,
recommended for combination with RCCS36 to
39, strongly recommended for combination with
RCCS39/IR, mandatory for combination with
RCCS39/XR
Active Pulse Output
/AP
One active pulse output
not with /KF2, /EF2, /UF2, /NM
NAMUR Switch
/NM
One pulse output acc. EN 60947-5-6 (NAMUR)
not with /AP
Tag Number
/BG
With customer specified tag number on name plate
max. 16 digits
HART Tag Number (Software Tag)
/BT1
With customer specified tag number for HART communication in converter
8 digits for tag, 22 digits for long tag
Gas Measurement
/GA
Gas measurement, special factory adjustments and settings
select affiliated RCCS3 with /GA
Combination with RCCS39/XR
/XR
Special converter adjustment with RCCS39/XR
mandatory for combination with RCCS39/XR
No Combination
/NC
No combination with detector
Customer Presetting
/PS
Presetting sheet with customer data
has to be issued with the order
Epoxy Coating
/X1
Epoxy coating of converter housing
Delivery to Japan
/PJ
For meters which are delivered to Japan with SI-unit preset
Delivery to Korea
/KC
With KC-mark for Korea
Cable glands
/AD2
2 pcs ANSI 1/2“ NPT / G1/2 adapter
only with cable conduit ´A´
Concentration Measurement
2)
/CST
/Cxx
Standard concentration measurement
Advanced concentration measurement, details see table „Advanced Concentration
Measurement Options“
Instruction Manuals
/IEn
/IDn
/IFn
Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French
n = 1 to 3 selectable
3)
n = 1 to 3 selectable
3)
n = 1 to 3 selectable
3)
Quick Delivery
/QD
Delivery within 24 hours from factory
not with /KF2, EF2, /FF2, /UF2, /PJ, /AD, /FB, /
GA, /QR1, /QR2, /QR3, /PS, /X1, /MB1
Special order
/Z
Special design must be specification an extra sheet
1)
Select affiliated RCCS3 with the same approval type (e.g. /KFx with /KS1).
2)
For detailed information please see TI 01R04B04-04E-E. Option /K6 of RCCS3 is recommended with concentration measurement.
3)
If no instruction manual is selected, only a DVD with instruction manuals is shipped with the instrument. More than 3 manuals of one language on request.