<8. EXPLOSION-PROTECTED TYPE INSTRUMENTS>

8-16

IM 01R01B30-00E-E 5th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

8.8 Intrinsically safe NEPSI (China) certified RAKD (/NS1)

Certificate No.

: GYJ101552

Type of protection

: Intrinsically safe Ex ia

Group

: IIC

Temperature Class

: T6

Ambient temperature

: -25°C ... +65 °C

Safety relevant maximum values of electronic transmitter :
Maximum voltage

: U

i

= 30 V

Maximum current

: I

i

= 100mA

Maximum power

: P

i

= 750 mW

Inner inductance

: L

i

= 0.73 mH

Inner capacity

: C

i

= 2.4nF

Pulse output:
Maximum voltage

: U

i

= 16 V

Maximum current

: I

i

= 20 mA

Maximum power

: P

i

= 64 mW

Inner inductance

: L

i

= 0 mH

Inner capacity

: C

i

= 0nF

Data of limit switches option /K1 to /K10 :
The following table shows the maximum safety parameters for intrinsic safe limit switches according the certificate
NEPSI GYJ06542X :

Standard

/K1 ... /K3

Fail Safe

/K6 ... /

K10

Type 2

Type 3

Type 2

Type 3

Ui [V]

16

16

16

16

Ii [mA]

25

52

25

52

Pi [mW]

64

169

64

169

Li [µH]

150

150

250

250

Ci [nF]

150

150

50

50

Max. ambient temperature for T6 [°C]

66

45

66

45

Max. ambient temperature for T5 [°C]

81

60

81

60

Max. ambient temperature for T4-T1 [°C]

100

89

100

89