beautypg.com

Rakd with nepsi- certification “intrinsic safe, China) (option /ns1), Rakd with peso- certification (india) – Yokogawa RAKD User Manual

Page 39: Rakd with kosha- certification (korea)

background image

IM 01R01B30-00E-E 5th edition January 01, 2013 -00

<7. TECHNICAL DATA>

7-9

All Rights Reserved. Copyright © 2003, Rota Yokogawa

RAKD with ATEX- certification “intrinsic safe ic”
(option /KS3)

Output signal :

4–20 mA / Pulse output / Limit switches

Explosion proof :

Ex ic IIC T6; Gc group II ; category 3G

Entity parameter :

see table 6

Temperature specification :

see table 7

RAKD with IECEx- certification “intrinsic safe”
(option /ES1)

Certificate :

IECEx DEK 12.0003X

Output signal :

4–20 mA / Pulse output / Limit switches

Explosion proof :

Ex ia IIC T6 ... T4 Gb

Entity parameter :
Table 8

Analog

output

Pulse

output

Limit

switch

type 2

/K1-/K3

Limit

switch

type 3

/K1-/K3

Limit

switch

type 2

/K6-/K8

Limit

switch

type 3

/K6-/K8

Ui [V]

30

16

16

16

16

16

Ii[ mA]

100

20

25

52

25

52

Pi [mW]

750

64

64

169

64

169

Li [mH]

0.73

0

0.15

0.15

0.1

0.1

Ci [nF]

2.4

0

150

150

30

30

Temperature specification :
Table 9

Configura-

tion

Max.

ambient

temperature

Max.

process tem-

perature

Temperature

class

Transmitter
4-20mA /
Pulse

65°C

65°C

T6

50°C

80°C

45°C

100°C

T5

38°C

135°C

T4

Limit
switch(es)
type 2

65°C

65°C

T6

80°C

80°C

T5

59°C

100°C

100°C

100°C

T4

73°C

135°C

Limit
switch(es)
type 3

24°C

65°C

T6

37°C

80°C

T5

34°C

100°C

57°C

80°C

T4

54°C

100°C

48°C

135°C

For the configuration where a transmitter is combined with
limit switches, the temperature class is determined by the
most restrictive combinations of maximum ambient temperature
and maximum process temperature.
Description of limit switch type 2 and 3 see IECEx certificates
from Pepperl & Fuchs:
- IECEx PTB 11.0091X ( SC2-NO) for /K1 to /K3
- IECEx PTB 11.0092X (SJ2-S.N) for /K6 to /K10

RAKD with IECEx- certification “intrinsic safe ic”
(option /ES3)

Output signal :

4–20 mA / Pulse output / Limit switches

Explosion proof :

Ex ic IIC T6; Gc group II ; category 3G

Entity parameter :

see table 8

Temperature specification :

see table 9

RAKD with NEPSI- certification “intrinsic safe”

(China) (option /NS1) :

Certificate :

GYJ101552

Output signal :

4–20 mA

Explosion proof :

Ex ia IIC T5/T6

Max. Tamb. :

65°C

Limit switches :

option /K1 to /K8, see certificates GYJ11.1505X

Entity parameter :
Table 10

Analog

output

Pulse

output

Limit

switch

type 2

/K1-/K3

Limit

switch

type 3

/K1-/K3

Limit

switch

type 2

/K6-/K8

Limit

switch

type 3

/K6-/K8

Ui [V]

30

16

16

16

16

16

Ii[ mA]

100

20

25

52

25

52

Pi [mW]

750

64

64

169

64

169

Li [mH]

0.73

0

0.15

0.15

0.1

0.1

Ci [nF]

2.4

0

150

150

30

30

Temperature specification :
Table 11

Max. ambient

temperature

Max. process

temperature

Temperature

class

65°C

65°C

T6

50°C

80°C

T6

45°C

95°C

T5

Description of limit switch type 2 and 3 see ATEX certificates
from Pepperl & Fuchs:
- PTB 99 ATEX 2219X ( SC2-NO) for /K1 to /K3
- PTB 00 ATEX 2049X (SJ2-S.N) for /K6 to /K10

RAKD with PESO- certification (India)

Option /KS1 must be selected. PESO- certificate is available
at your Yokogawa Sales Office.

RAKD with KOSHA- certification (Korea)

Option /ES1 must be selected.
Same data as for IECEx certification.

Analog

output

Pulse

output

Limit

switch

type 2

/K1-/K3

Limit

switch

type 3

/K1-/K3

Limit

switch

type 2

/K6-/K8

Limit

switch

type 3

/K6-/K8

Ui [V]

30

16

16

16

16

16

Ii[ mA]

100

20

25

52

25

52

Pi [mW]

750

64

64

169

64

169

Li [mH]

0.73

0

0.15

0.15

0.1

0.1

Ci [nF]

2.4

0

150

150

30

30