TROUBLESHOOTING TIPS

CAUTION: Maintenance

DISASSEMBLY

1. Replacement parts may be available at the store where you purchased your faucet.

2. When replacement parts are not available, please write or call Price Pfister Consumer

Service.

3. Always turn off water and relieve pressure before working on your shower panel.

NOTE: Trim Care

Cleaning Instructions:

For all Handles and decorative finishes, use only a soft damp cloth to clean and shine. Use

of polish, detergents, abrasive cleaners, organic solvents or acid may cause damage. Use

of other than a soft damp cloth will nullify our warranty!

Special Trim:

Trim products which contain Porcelain or other similar substance are not acceptable for public

areas or Commercial use. Installation of Said Trim is at Users Risk!

18 THERMOSTATIC CARTRIDGE REMOVAL

Remove Button (18E). Using a 3/32" Allen Wrench, remove set screw (18D), then

Knob Assembly (18C). Remove Screw (18B) then pull out Thermostatic Cartridge

Assembly (18A). Reassemble unit in reversed order.

19 DIVERTER CARTRIDGE REMOVAL

Remove Button (19B). Using a 3/32" Allen Wrench, remove set screw (19C), then

remove Diverter Handle (19A). Unscrew Retainer Rings (19D), (19E), and 19F) and

remove Diverter Cartridge (19G). Reassemble in reversed order.

18 CÓMO SACAR EL CARTUCHO TERMOESTÁTICO

Quite el botón (18E). Use una llave Allen de 3/32 PULG (2,4 mm) para sacar el

tornillo de ajuste (18D) y luego la unidad de la perilla (18C). Saque el anillo de

retención (18F) del cuerpo de la válvula (18G). Quite el tornillo de ajuste (18B)

para liberar la unidad del cartucho termoestático (18A). Vuelva a montar la unidad

siguiendo el orden inverso.

18 RETRAIT DE LA CARTOUCHE THERMOSTATIQUE

Enlever le bouton (18E). À l'aide d'une clé Allen de 3/32 po, enlever la vis pression

(18D), puis le bouton de réglage (18C). Enlever l'anneau de retenue (18F) du

corps du robinet (18G). Enlever la vis pression (18B) pour libérer la cartouche

thermostatique (18A). Remonter le tout dans l’ordre inverse.

19 CÓMO SACAR EL CARTUCHO DEL DESVIADOR

Quite el botón (19B). Con una llave Allen de 3/32" (2,4 mm), saque el tornillo de

ajuste (19C), luego la manija del desviador (19A). Desatornille los anillos de re-

tención (19D), (19E), and 19F) y saque el cartucho del desviador (19G). Vuelva a

montar siguiendo el orden inverso.

19 RETRAIT DE LA CARTOUCHE DU MITIGEUR

Enlever le bouton (19B). À l'aide d'une clé Allen de 3/32 po, enlever la vis pression

(19C), puis la manette du mitigeur (19A). Dévisser les anneaux de retenue (19D),

(19E) et (19F) puis retirer la cartouche du mitigeur (19G). Remonter le tout dans

l’ordre inverse.

.

Temperature or Flow does not remain constant.

The Thermostatic Cartridge Assembly (18A) must be cleaned. Shut off water supply.

Remove Button (18E) then Set Screw (18D). Remove Knob Assembly (18C) from

Cartridge Assembly (18A) Unscrew Retainer Ring (18F), then remove Set Screw

(18B). Remove Thermostatic Cartridge Assembly (18A) from Valve Body (18G).

Inspect inlets for sediment and flush with water. Inspect O-Rings (18H) for dam-

age. Reassemble in reversed order then turn water supply on. If problem persists,

replace Cartridge Assembly (18A).

.

Dripping either from Hand-Held Shower, Head Shower or Body Sprays

Clean the Cartridge Assembly (18A). Check to ensure the O-Rings (18H) on Car-

tridge (18A) are in place. Reassemble Cartridge and Knob Assembly. Turn on the

water and test. If the unit still leaks, replace the Cartridge.

.

Make sure that both hot and cold water inlets are turned on.

.

No water flow or water not warm enough.

Check if water heater is working properly.

.

Water Flow is very low.

Check the Cartridge Assembly (18A) for debris.

.

Water starts out cold and becomes hotter as handle is rotated clockwise.

This is a potentially hazardous situation and should be corrected before using the

unit. Check the hot and cold inlet positions (hot left, cold right).

.

Water flows from the Body Sprays or Hand-Held Shower when Head

Shower in use.

The seal inside the Diverter Mechanism (19G) may have been dislodged. The Di-

verter (19G) may need replacement.