beautypg.com

Ordering information output rating curve, Unit dimensions, Warnings – Watlow DIN-A-MITE Style D User Manual

Page 3

background image

DIN-A-MITE Style D, solid-state power controller

Part Number

D D 1 0 - __ __ __ __ - __ __ __ __

Phase
1

= Single-phase, one

controlled leg

Cooling and Current Rating
0

= Natural convection; current rating

80A @ 50°C (122°F)
Note: See the output rating curve
for the current rating at other
temperatures.

Line and Load Voltage
02

= 24 to 48VÅ (ac)

24

= 120 to 240VÅ (ac)

48

= 277 to 480VÅ (ac)

60

= 277 to 600VÅ (ac)

Input Control Signal
C0

= 4.5 to 32VÎ (dc) contactor

F0

= 4 to 20mAÎ (dc) proportional

F1

= 12 to 20mAÎ (dc) proportional

K1

= 22 to 26VÅ (ac) contactor

K2

= 100 to 120VÅ (ac) contactor

K3

= 200 to 240VÅ (ac) contactor

Current Sensing or Alarm
0

= None

1

= Load current transformer

S

= Shorted SCR alarm

User Manual Language
0

= English

1

= German

2

= Spanish

3

= French

Custom Options
00

= Standard

Ordering Information

Output Rating Curve

0

5

10 15 20 25 30 35 40 45 50 55 60 65 70

25

30

35

40

45

50

55

60

65

70

75

80

85

Current (Amperes) Into a Resistive Load

M

a

x

im

u

m

A

m

b

ie

n

t

T

e

m

p

e

ra

tu

re

I

n

s

id

e

C

a

b

in

e

t

(°

C

)

DIN-A-MITE Style D Natural Convection at 100% on

75 80 85 90 95 100 105

WATLOW DIN-A-MITE Style D User’s Manual

3

з

У

3

5

203 mm
(8.00 in)

203 mm (8.00 in) clearance for air

flow and bending radius

203 mm
(8.00 in)

203 mm (8.00 in) clearance for air flow and bending radius

178 mm
(7.00 in)

185 mm

(7.28 in)

13 mm

(0.50 in)

1

3

m

m

(

0

.5

i

n

)

c

le

a

ra

n

c

e

fo

r

a

ir

f

lo

w

9507

Unit Dimensions

Allowance For No. 10 Fastener

Metric = M5

54 mm

(2.13 in)

13 mm
(0.50 in)

67 mm

(2.63 in)

67 mm

(2.63 in)

61 mm

(2.38 in)

239 mm

(9.41 in)

66 mm

(2.58 in)

64 mm

(2.50 in)

Grounding Screw

9.5 mm minimum diameter (3/8 in to 16 UNC)

Top

Side

Mounting
Footprint

ç

WARNINGS:

Ó

3 WARNING: Only authorized and qualified

personnel should be allowed to install and
perform preventive and corrective maintenance
on this unit. Failure to do so could result in
damage to equipment, and personal injury or
death.

5

WARNING: Hot surface, do not touch the heat
sink. Failure to follow this guideline could result
in personal injury.

Note:

• Recommended fusing options to meet 200KA SCCR, type 1 and

2 approved. All other fuse combinations are defaulted to 5KA
SCCR per UL508A and NEC guidelines.

Watlow part number:

0808-0096-0000

Bussmann part number:

170N3437