Dimensions
Dip Switches and Slide Switch
The Dip Switches and Slide Switch are located in the bottom of the FP unit. Loosen the screws
of the cover with a Phillips head screwdriver and then remove the cover. After setting the dip
switches and slide switches, reinstall the cover and screws with the screwdriver. The tightening
torque for those screws is 0.5 ~ 0.6 N•m.
Only the settings when the power supply is turned on is effective to the Dip Switches and the
Slide Switch. After changing the settings of the Dip Switches and the Slide Switch, be sure to
restart your FP unit
SW1
• SW1-2 Dip Switch SW1-2 is used to display or hide the OSD.
To hide the OSD, set the switch to ON. To display the OSD, set the switch to OFF.
The default setting is OFF. (OSD is displayed.)
SW2
Switch
Setting
SW1-1 Reserved (Always OFF) SW1-5 Reserved (Always OFF)
SW1-2 Display/Hide the OSD
SW1-6 Reserved (Always OFF)
SW1-3 Reserved (Always OFF) SW1-7 Reserved (Always OFF)
SW1-4 Reserved (Always OFF) SW1-8 Reserved (Always OFF)
Switch
Setting
Slide Switch is used to switch the data input/output (command
control) method on the touch panel between USB and RS-232C
(Serial). The default setting is RS-232C.
Top View
Front View
Side View
Unit:
mm [in]
center of display area
419[16.50]
460[18.11]
12.7
[0.50]
77.7
[3.06]
3.5
[0.14]
352
[13.
86]
39
0[15.
35]
2.
5[0.
10]
center of unit
Dip Switches(SW1)
Slide Switch(SW2)
Bottom View
Cover
1 2 3 4 5 6 7 8
ON
USB
232