beautypg.com

Hose reel operations manual – Reelcraft Nordic Series 4800 Reels User Manual

Page 3

background image

Flexible

Connection

Victaulic

Connection

Hose Reel Operations Manual

www.reelcraft.com

Page 3

VICTAULIC INLET SWIVELS

NOTE: Victaulic - Type swivel joint inlet connections must be

carefully aligned. Two victaulic connections, correctly installed,
allow adequate flexibility for smooth rotation.

1. Connect victaulic coupling onto inlet swivel fitting and inlet

supply line.

2. Adjust inlet supply line to verify flexibility exists for proper

alignment.

3. With control valve open, fully extend and charge hose

to purge system of gases. When fluid appears at control
valve, close valve. This prevents flattening of hose and ex-
cessive presure on drum when fluid supply is reinitialized
at a later time.

NOTE: Failure to use flexible connector with any live reel will

void warranty.

For larger reels, gooseneck may be removed from reel to fit to
hose. Note that if the reel has a welded or threaded riser in the
fluid path assembly, it cannot be removed to attach the hose.

CAUTION: Do not connect the output hose to the gooseneck

(1) until after the reel is installed and motor connections are
complete. Fill the hose before winding on the reel to prevent
excessive pressure on the
drum when hose is filled.

1. Apply thread compound

to connecting gooseneck
(1) and output hose fitting
threads (2).

2. Hand thread output hose

fitting (2) into gooseneck
(1).

3. Using a wrench, firmly

hold gooseneck (1) while
tightening out put hose fit-
ting (2).

REPLACING THE SPRING CASE

Ensure reel base is fastened down before attempting to re-
place the spring case.

CAUTION: Remove all spring tension before replacing the

spring case!

DO NOT ATTEMPT TO OPEN SPRING CASE!

Serious injury may occur.

1. Loosen and remove hardware (1) securing spring case (2)

to frame.

2. Slide horizontally off frame and shaft (5).
3. Leave spring arbor (3) and key (4) on shaft (5).
4. Safely discard old spring case and install new spring case.
5. Install fasteners.
6. Tension reel acccordingly (see Install / Replace Hose).

REPLACING THE SWIVEL

CAUTION: Remove supply line pressure before performing the

following procedures.

1. Remove supply line

(2) from the swivel
(1) or inlet.

2. Remove swivel (1)

from inlet shaft (3).

3. Install replacement

swivel by reversing
steps 1 & 2.

REPLACING “U” CUP SEALS ON NORDIC SWIVELS

1. Remove supply line (3) from inlet adaptor (1).
2. Remove all three bolts (2).
3. Pull seal from recess inside of

inlet adaptor.

4. Examine new seal (5) and ring

(4) to check for damage.

5. Moisten face of seal with lu-

bricant and replace into inlet
adaptor (1).

6. Bolt adaptor back in place and

re-install supply line.