Reelcraft Series 5005 Spring Driven Hose Reels (Low and Medium Pressure xxxxOLP, xxxxOMP) User Manual
Operating instructions, Series 5005 spring driven hose reels, Safety
![background image](/manuals/358382/1/background.png)
1. Do not use reel at higher pressures or temperatures than listed on
the back of this bulletin.
2. Remove all spring tension before beginning dissassembly process.
SAFETY
A5805 OLP A5806 OLP
A5805 OMP
A5835 OLP A5850 OLP
A5835 OMP
Four 5/16” diameter mounting holes
Operating Instructions
Series 5005 Spring Driven Hose Reels
Low and Medium Pressure Model Numbers:
Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725
Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605
[email protected] • www.reelcraft.com
Form# 907-897 Rev: 1/2012
Dimensions
A
17 1/2”
B
16 1/2”
C
9 3/4”
D
2 1/2”
E
6”
A
B
C
D
E
INSTALLATION:
A flexible hose connection must be used between the hose reel inlet and the source of supply to prevent possible
misalignment and binding.
LUBRICATION:
Hose reel spring and bearings are factory lubricated and require no further lubrication.
REPLACING HOSE: 1. Wind spool flange clockwise-facing swivel-until spring is tight.
2. Back off three turns and latch.
3. Insert hose through roller guide.
4. Connect hose fitting to swivel joint and secure hose with clamps.
ADJUSTMENTS:
To adjust spring tension, add or remove wraps of hose from the spool, one wrap at a time until desired tension is
obtained.
REPAIRS:
Extensive repairs should be performed only by an authorized serviceman or factory to avoid damage which may
void your warranty. Remove all spring tension before beginning disassembly process.
MOUNTING:
The hose reel is equipped with a universal mounting bracket so that it can be mounted on the floor, wall or
ceiling; whichever place is convenient. The hose guide arm can be moved to the position desired by removing
the screws fastening the guide bracket to the reel base. Shift the guide arm bracket so the hose comes off the
reel at the desired position and replace the screws.
NOTE: For proper installation in wall mount applications, ensure
reel is mounted with inlet on the right as you are facing the reel. Failing to do so could cause latching issues.