Rapid Air Corporation

A. Acceleration Start. The ACCEL is factory set at approximately .2 seconds.
To readjust to different times, set the knob to the desired position as indicated in
Fig 2.

B. Deceleration. The DECEL is factory set to provide a ramp-down time of .2
seconds. To change the ramp-down time, adjust the DECEL trimpot as indicated
in Fig 2.

C. Minimum Speed Adjustment. If a higher than zero minimum speed is
desired, readjust the minimum speed by turning the speed control knob to zero
setting (full CCW position). Then adjust the Min. Speed Trimpot to the desired
setting.

D. Maximum Speed Adjustment. Turn Speed Control Knob to full speed
(maximum CW position). Adjust max. speed trimpot to new desired setting.