beautypg.com

Rapid-Air PALLET MASTER (PMD): PMD35 & PMD50. 115VAC, 1PH, 60HZ User Manual

Page 19

background image

Rapid Air Corporation

1.

R1 & R3 pot on 69100034 board not correctly adjusted.

a. Readjust pots so table stops. Call factory.

UNIT TURNS BUT WON’T JOG

1.

Selector switch not in jog position.

a. Select jog.

2.

Jog pot on 69100053 board not adjusted correctly.

a. Adjust pot. Call factory.

3.

Maximum speed pot on Ramm board set too low.

a. Adjust pot.

UNIT ON BUT MOTOR WON’T RUN. (ARMATURE VOLTAGE
PRESENT ON RAMM BOARD)

1. Check TB-4 of 69100035 board. Terminal 1&2.

a. If voltage not present, replace 69100035 board. Call factory.

2. Check motor wiring

a. Replace motor cord or correct motor wiring. Call factory.

3. Check motor

file:///C|/Web_develop/Pallet%20Master.htm (22 of 46) [12/10/2001 3:38:23 PM]