WINCH FRAME MOUNTING

Use (8) 3/4" diameter grade 5 or better bolts to attach mounting frame to the wrecker.

CABLE INSTALLATION

1. Unwind cable by rolling it out along the ground to prevent kinking. Securely wrap end of wire rope,

opposite hook, with plastic or similar tape to prevent fraying.

2. Insert the end of cable, opposite hook end, into the hole in drum barrel. Secure cable to drum

barrel, using setscrew furnished with winch.

TIGHTEN SETSCREW SECURELY.

3. Carefully run the winch in the “reel-in” direction. Keeping tension on end of cable, spool all the

cable onto the cable drum, taking care to form neatly wrapped layers.

HYDRAULIC SYSTEM REQUIREMENTS

Refer to the performance charts to properly match your hydraulic system to RPH-45,000T winch performance.
The charts consist of:

(1) Line pull (lb.) first layer vs. working pressure (PSI) and (2) Line speed (FPM) first layer vs. flow (GPM).

Performance is based on a motor displacement of 9.6 cubic inches with 25 GPM maximum flow rate. See
page 14 for motor port size.

INSTALLER MUST DETERMINE TYPE OF
EMERGENCY STOP REQUIRED. A MANUAL
CONTROL VALVE ALSO SERVES AS AN
EMERGENCY STOP VALVE. AN EMERGENCY
STOP VALVE MAY BE REQUIRED WITH OTHER
TYPES OF CONTROL VALVES.

SYSTEM REQUIREMENTS:

2200 PSI RELIEF VALVE SETTING

25 GPM FLOW RATE*

10 MICRON NORMAL FILTRATION

1000 PSI MAXIMUM BACK PRESSURE

EMERGENCY STOP VALVE

DUAL-A & B PORT CONTROL

WITH BRAKE RELEASE SHUTTLE

*CAUTION: DO NOT EXCEED 30 GPM, IF EXCEEDED, MOTOR AND WINCH MAY BE DAMAGED

TYPICAL LAYOUT

PORT

BRAKE

MOTOR

B

A

EMERGENCY STOP

CONTROL VALVE/

HIGH PRESSURE LINE

RATED LOAD:

RESERVOIR

FLUID

LOW PRESSURE LINE

2200 PSI

25 GPM

PRESSURE AT

MAX. FLOW &

3 POSITION

4 WAY VALVE

(MOTOR SPOOL)

PUMP INLET
LINE (SUCTION)

PUMP