beautypg.com

Ramsey Winch RPH 10000XT User Manual

Page 6

background image

4

HYDRAULIC SYSTEM REQUIREMENTS

Refer to the performance charts below to properly match your hydraulic system to the winch performance. The
charts consist of: (1) line pull (LB) first layer vs. working pressure (PSI) and (2) line speed, first layer (FPM) vs.
flow (GPM). STATIC (solid line) refers to hoisting a suspended load from rest; DYNAMIC (dotted line) refers to
maintaining the motion of a moving load. A cylinder spool directional control valve is recommended.


*CAUTION: DO NOT EXCEED 20 GPM. IF EXCEEDED, MOTOR AND WINCH MAY BE DAMAGED.

PERFORMANCE CHARTS

SYSTEM REQUIREMENTS:

2100 PSI RELIEF VALVE SETTING

15 GPM FLOW RATE*

10 MICRON NOMINAL FILTRATION

INSTALLER MUST DETERMINE TYPE OF

EMERGENCY STOP REQUIRED. A MANUAL

CONTROL VALVE ALSO SERVES AS AN

EMERGENCY STOP VALVE. AN EMERGENCY

STOP VALVE MAY BE REQUIRED WITH OTHER

TYPES OF CONTROL VALVES.