CONDITIONS

POSSIBLE CAUSE

CORRECTION/ACTION

DRUM WILL NOT ROTATE
AT NO LOAD

Winch not mounted squarely, causing end bearing
to bind up

Check mounting. Refer to Winch Mounting, page 4.

Brake damaged

Inspect and replace brake

Gears damaged

Inspect and replace damaged gears

DRUM WILL NOT ROTATE
UNDER LOAD

Load greater than rated capacity of winch

Refer to Specifications page 3 for line pull rating.

Low hydraulic system pressure

Check pressure. Refer to Hydraulic Systems per-
formance charts page 6.

WINCH RUNS TOO SLOW

Low hydraulic system flow rate

Check flow rate. Refer to Systerm Requirements and
Typical Layout page 6.

Motor worn out

Replace motor

DRUM WILL NOT
FREESPOOL

Clutch not disengaged. Check Adjustment of Manual
Shifter, page 9.

Check Operation, page 5.

Winch not mounted squarely, causing end bearing
to bind up

Check mounting. Refer to Winch Mounting, page 4.

BRAKE WILL NOT
RELEASE

Brake damaged

Inspect and replace brake

CABLE BIRDNESTS WHEN
CLUTCH IS DISENGAGED

Drag screw improperly adjusted

Adjust nylon drag screw. Refer to Cable Installation,
page 4.

EXCESSIVE NOISE

Hydraulic system flow too high

Check flow rate. Refer to Typical Layout page 6.

DRUM CHATTERS IN
“REEL IN” DIRECTION

Low hydraulic system flow rate

Check flow rate. Refer to Typical Layout page 6.

Low hydraulic system relief pressure setting

Check relief valve setting.

OIL SEEPAGE FROM
BREATHER VENT OF
BRAKE HOUSING

Brake piston not sealing properly

Replace o-ring and backup rings on brake piston.
Refer to pages 8 and 10.

GREASE SEEPAGE FROM
JOINTS IN MOTOR

Grease applied to seals during assembly by motor
manufacturer.

NONE. Normal condition during the first few times
the winch is operated.

TROUBLESHOOTING GUIDE

7