beautypg.com

Programming, Entering program mode, Cycle and error count – Alliance Laundry Systems UW125AV User Manual

Page 6

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

4

F232226

Programming

NOTE: The machines are factory-programmed

with basic cycles to make the units operational

without programming at the installation.

Entering Program Mode

1. Remove top cover of control panel.
2. Locate Program/Run switch on the computer

board. This is accessed through a cutout in the

metal control unit cover. This switch protrudes

from the rear of the electronic control unit cover.

3. Flip switch to the left (as seen from the front of

machine) to enter Program Mode.

4. Display will show temperature.

Cycle and Error Count

The control logs cycle count (total of all cycles

completed).

• To read, enter Program Mode.
• Press START (enter) keypad. Display will show

the cycle count.

• Press START (enter) keypad. Display will show

certain error conditions that may have been

recorded by the control.

• Read the information when consulting technical

assistance as needed.

• Step through the error log by pressing START

keypad repeatedly until display reverts to normal

Program Mode (“0000” or a temperature).

Setup Mode

NOTE: In Setup Mode, certain machine functions

can be configured. The settings in this mode are

related to how the machine is equipped from the

factory. Usually, these settings would not be

changed.

NOTE: Enter Setup Mode through the Program

Mode.

1. Press * keypad. Display will show “FAr” or

“CEL”.

NOTE: This selects whether temperatures display

in degrees Fahrenheit (F) or Celsius (C), if control

is equipped with a temperature sensor. Change

selection by pressing

or keypad.

NOTE: Changing degrees “FAr” or “CEL” only

has an effect if the control has a temperature probe

connected and/or heat capability.

2. Press START keypad.
3. Select “HEAt” or “noHt”. Change the selection

by pressing the

∧ or ∨ keypad.

NOTE: If set for “HEAt”, the control has heat

capability enabled. The washer-extractor MUST

have electric or steam heat, and a temperature

probe. If display shows “noHt”, or if the message

“HEAt” or “noHt” does NOT display, the control

does NOT have heat capability.

4. Press START keypad to continue to the next step.
5. Select “AFIL” or “SUP5”. For “SUP5”, a fifth or

sixth supply can be programmed in a cycle step.

“AFIL” allows auxiliary fills to be programmed

to low, medium or high water level in a cycle

step.

6. Press START keypad.
7. Select “tFIL” or “ntFL.” “tFIL” allows a

temperature controlled fill to be programmed for

any segment. Select “ntFL” to disable the

feature.

8. Press START keypad.
9. Select “COOL” or “noCL.” “COOL” enables an

automatic cooldown feature allowing cold water

to flush into wash before a drain if temperature is

140°F (60°C) or above. Select “noCL” to disable

feature.

10. Press START keypad.

11. Select “bEEP” (control sounds beeper during

Add Bleach [Supply 2]) or “nobP” (control does

NOT sound beeper during Add Bleach

[Supply 2]). Change selection by pressing

∧ or

keypad.

12. Press START keypad.
13. Select “Adv” or “noAd”. “Adv” enables the

rapid advance feature. Select “noAd” to disable

the feature.

14. Press START keypad.