beautypg.com

Alliance Laundry Systems UW125AV User Manual

Page 13

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming

11

F232226

Temperature Controlled Fill

Display shows temperature in degrees F or C.

Display will show degrees F if configured for “FAr”

in Setup Mode, or degrees C if configured for

“CEL” in Setup Mode. Range is 75°F to 200°F, or

00F (no heat for segment), or 25°C to 93°C, or 00C

(no heat for segment).
Press the

∧ keypad to increase, or ∨ keypad to

decrease temperature in one-degree increments. The

control will energize heat and pause cycle timing for

up to 40 minutes until the programmed temperature is

first reached.

NOTE: If temperature not reached after

40 minutes, control resumes cycle.

After cycle resumes, control will attempt to maintain

programmed temperature if it senses water in the

machine.
If display shows “drAI”/“nodr” during segment

programming, a drain step option can be selected.

Select “drAI” for a drain step followed by an optional

spin. Select “nodr” for no drain step. The machine will

proceed directly to the next segment if “nodr”. Change

the selection by pressing the

∧ or ∨ keypad. Press

START to continue.
If “drAI” is selected (or if your model does not provide

the option of selecting “drAI”/“nodr”), the display will

show “SPIn” one second, “tI

n

E” one second, and then

the time for spin: “00” (no spin) or 60-240 seconds.

Change the selection by pressing the

∧ or ∨ keypad.

Press START to continue.

Rinse 1 – Rinse 6

NOTE: Programming a time other than “00” for

this step will make the RINSE indicator LED light

while this step is running, but not in Program

Mode.

The main display shows “rIN1” indicating you are in

the Rinse segment (number will represent Rinse cycle

selected 1-6). Press START keypad. Display shows the

time for agitation during the step: “00” (skips

segment) or 2-30 minutes. This is the time after the fill

and before the drain and does not include spin time.

Press the

∧ or ∨ keypad to alter the selection, or the

START keypad to continue.
Display shows “CFIL”, “HFIL”, “bFIL” (for cold, hot,

warm [both]) or “AFIL”. Press the

∧ or ∨ keypad to

alter the selection, or the START keypad to continue.
Display shows “LO”, “

n

Ed”, or “HI” for low, medium,

or high water level, respectively. Press the

∧ or ∨

keypad to alter the selection, or the START keypad to

continue.
Display shows “SUP0”, “SUP1”, “SUP2”, “SUP3”,

“SUP4”, “SUP5”, “SUP6”, or “SUP7” indicating no

supply, supply 1, supply 2, supply 3, supply 4, supply

5 (supply 1 and supply 2 together), supply 6, or supply

7 (supply 3 and supply 4 together). Press the

∧ or

∨ keypad to alter the selection, or the START keypad

to continue.

NOTE: “SUP5” and “SUP6” appear ONLY if

control is configured for “SUP5” (spare mode set

up to operate as an EXTRA supply signal for

external chemical) in Setup Mode. If the alternate

function for the spare output is selected (“AFIL”),

the output will function as an additional fill valve

signal with a programmable water level. In this

case, extra supply function would NOT be

available.

If programmed for “SUP2”, the ADD BLEACH

indicator LED light turns on and the buzzer sounds

while supply 2 is on.
Press the

∧ or ∨ keypad to alter the selection or

START keypad to continue.

This manual is related to the following products: