Programming

15

F232226

NOTE: ON appears ONLY where motor control

outputs are on (otherwise they are off). Outputs

referenced are on control unit fuse board. Outputs

are as labeled on the fuse board.

NA – Not Applicable

Table 4 (Continued)

Pause 5 seconds, then Reverse
wash speed – 60 seconds, pause
several seconds before entering
drain (next step)

Display shows ‘rEv’

Outputs: Motor operates wash speed reverse; drain closed

Drain (cannot advance to spin
here)

For 2 speed models: Display flashes “drAI”/“For” (keypad RINSE LED on)
For variable-speed models: Display flashes “drAI”/“For” while operating in low speed
forward; then flashes “drAI”/“dISt” while operating at distribution speed.
If balance fails, repeats the “drAI”/“For” then “drAI”/“dISt” sequence above and balance
indicator is on during “drAI”/“For” message (rebalance attempt). Tries up to 10 times in
TEST cycle, then aborts test cycle.

Outputs: Drain closed for first part of step (less than 20 seconds), then drain off.
2 speed models: Wash speed forward
Variable-speed: Forward during “drAI”/“For”; distribution during “drAI”/“dISt”
.

Spin: 2 minutes

Certain models display “SPIn” (keypad SPIN LED on)
while other models display shows “HI 1” (keypad SPIN LED on)

Outputs: Spin (low spin for variable-speed – refer to motor chart below)

Highest Spin speed (variable-
speed models ONLY):
2 minutes

For 2 speed models: this step is skipped, goes to coast (the next step)
For variable-speed models: display shows “HI 2” (keypad SPIN LED on) or “HI”

Outputs: Highest spin speed selected (refer to motor chart below)

Coast

Displays “SdLY” (spin delay coast)

Outputs: All off

Stop routine

Display shows “01” (1 minute remaining). Agitates briefly then unlocks the door, shows
“doNE” while sounding the buzzer 10 seconds; “doNE” shows for 20 more seconds.
(DOOR LED on while showing “doNE”, meaning “door ready to open”).

Motor Speed Chart

Variable-Speed Motor Control

Outputs

Fixed Speed and

2 Speed Motor

Outputs

STF

STR

RH

RM

RL

Fwd

Rev

Spin

Motor off (no rotation)

Wash speed forward

ON

ON

ON

Wash speed reverse

ON

ON

ON

Distribution (variable-speed ONLY)

ON

ON

NA

NA

NA

Lowest spin (low spin speed “HI 1” for
variable-speed)

ON

ON

ON

ON

Medium spin (“HI 2” – variable-speed ONLY)

ON

ON

ON

NA

NA

NA

Highest spin (“HI 3” – variable-speed ONLY)

ON

ON

ON

NA

NA

NA