Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718117 Spirit II 400 User Manual
Page 95

Spirit II User’s Manual
Section 5: Torch Consumables and Cutting Charts
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
5-25
Stainless Steel - 100 Amps - H17 Plasma / Nitrogen Shield
Copper Electrode
(H17 = 17.5% Hydrogen / 32.5% Argon / 50% Nitrogen)
This gas combination gives the best cut quality and minimum dross levels
Shield Cap
Nozzle
Electrode
277146
277126
277133
Outer Cap
Retaining Cap
Swirl Ring
Torch Head
284150
277113
277141
279100
Imperial*
Material
Thickness
Preflow
Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(in)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm)
(in)
(in)
(msec)
(in)
3/16
28
72
40
67
138
115
.105
.200
300
.100
1/4
140
100
.125
.225
400
.105
3/8
152
65
.180
.250
500
Metric*
Material
Thickness
Preflow
Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(mm)
(psi)
(psi)
(psi)
(psi)
(volts)
(mm/m)
(mm)
(mm)
(msec)
(mm)
5
28
72
40
67
138
2865
2.7
5.1
400
2.5
6
139
2625
3.0
5.5
2.7
Marking* – For All Material Thicknesses
Type of Gas
Preflow Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Marking
Height
Initial
Height
Pierce
Time
(Plasma) (Shield)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm) (mm/min) (in) (mm) (in) (mm) (msec)
Nitrogen Nitrogen
N/A
25
25
N/A
130
250
6350
.100 2.5 .100 2.5
0
Argon** Nitrogen**
N/A
50
25
N/A
80
100
2540
.110 2.8 .100 2.5
0
* Use an arc transfer height (ignition height) of .200” (5.1 mm) for cutting and .100” (2.5 mm) for marking.
** Only available on systems with the Automatic Gas Console.