Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718117 Spirit II 400 User Manual
Page 83

Spirit II User’s Manual
Section 5: Torch Consumables and Cutting Charts
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
5-13
Mild Steel - 30 Amps - Oxygen Plasma / Oxygen Shield
Copper Electrode
Shield Cap
Nozzle
Electrode
277145
277120
277130
Outer Cap
Retaining Cap
Swirl Ring
Torch Head
284150
277153
277140
279100
Imperial*
Material
Thickness
Preflow
Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(ga)
(in)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm)
(in)
(in)
(msec)
(in)
20
.036
35
77
6
75
120
105
.080
.110
100
.062
18
.048
121
97
.090
16
.060
125
78
.105
200
.065
14
.075
126
65
12
.105
127
55
.070
11
.120
129
50
.120
.125
300
10
.135
131
40
Metric*
Material
Thickness
Preflow
Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(mm)
(psi)
(psi)
(psi)
(psi)
(volts)
(mm/m)
(mm)
(mm)
(msec)
(mm)
1
35
77
6
75
120
2615
2.0
2.8
100
1.6
1.5
124
2020
2.6
200
1.7
2
126
1615
2.7
2.5
1455
1.8
3
128
1285
2.9
3.1
300
Marking* – For All Material Thicknesses
Type of Gas
Preflow
Plasma
Shield
Postflow
Arc
Voltage
Travel
Speed
Marking
Height
Initial
Height
Pierce
Time
(Plasma) (Shield)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm) (mm/min) (in) (mm) (in) (mm) (msec)
Nitrogen Nitrogen
N/A
25
25
N/A
145
250
6350
.177 4.5 .100 2.5
0
Argon**
Air**
N/A
50
25
N/A
66
100
2540
.100 2.5 .100 2.5
0
* Use an arc transfer height (ignition height) of .100” (2.5 mm) for cutting and marking.
** Only available on systems with the Automatic Gas Console.
(Revised 04/26/2013)