beautypg.com

Installation, Technical specifications - sae-400 – Lincoln Electric IM10122 SAE400 User Manual

Page 7

background image

A-1

INSTALLATION

SAE-400

®

A-1

TECHNICAL SPECIFICATIONS - SAE-400

®

(K1278-15)

Make/Model

Description

Speed (RPM)

Displacement

Starting

Capacities

System

269 cu. in

Fuel: 29.0 gal.

(4.4 L)

109.8 L

K1278-15
Perkins
1104A-44 Diesel

4 cylinder

High Idle 1800

Bore x Stroke

12VDC battery

Oil: 10.1 Qts.

Engine

64.4 HP @

Low Idle 1100

& Starter

9.6 L

Not EPA Tier 4

1710 RPM

Full Load 1725

Compliant

4.13” x 5.00”

Export Only

(105.0 mm x 127.0mm)

Coolant: 3.4 gal.

12.8 L

INPUT - DIESEL ENGINE

RATED OUTPUT - WELDER

HEIGHT

WIDTH

DEPTH

WEIGHT

49.80 in.

27.70 in.

83.10 in.

2286 lbs.

1,264.9 mm

703.6 mm

2,110.7 mm

1037 kg.

OUTPUT - WELDER AND GENERATOR

Duty Cycle

(1)

Welding Output

Volts at Rated Amps

60% (NEMA)

500 amps

40 volts

100% (NEMA)

400 amps

36 volts

100% (Lincoln Plus)

400 amps

40 volts

Welding Range

Open Circuit Voltage

Auxiliary Power
120/240 VAC

80 - 575 Amps

97 Max. OCV

10,000 Watts, 60 Hz., Single Phase

@ 1800 RPM

13,000 Watts, 3 Phase Auxiliary, 240V
100% Duty Cycle

PHYSICAL DIMENSIONS

(1)

Based on a 10 minute period.

RECEPTACLES

AUXILIARY POWER CIRCUIT BREAKER

1 - 120VAC Duplex NEMA (5-20R)

2 - 20 amp for 120VAC Duplex NEMA

1 - 120VAC European (IEC-309)

1 - 15 amp for 120VAC European (IEC-309)

1 - 240VAC Duplex NEMA

1 - 15 amp (2 -pole) for 240 V Duplex and European (IEC-309)

1 - 240VAC European (IEC-309)
1 - 240VAC (15-50R) NEMA 3 Phase

1 - (30ma), (RCD) Residual Curret Detector

1 - 120VAC / 240VAC (14-50R) NEMA 1 Phase

1 - 50amp (3-pole), 240VAC Circuit Breaker

RECEPTACLES AND CIRCUIT BREAKERS