Operation – Lincoln Electric IM10122 SAE400 User Manual

Page 15

background image

B-4

OPERATION

B-4

AUXILIARY POWER CONTROLS

120 VAC Receptacles

One 20 amp, (each side) 120VAC (5-20R) NEMA
duplex receptacle provides 120VAC for auxiliary
power.

One 120V (European IEC-309) 16 amp receptacle. IP44
rated.

One 120V/240V (14-50R) 1 phase 50 amp NEMA style
receptacle.

The auxiliary power receptacles should only be used
with three or four wire grounded type plugs or
approved double insulated tools. The current rating of
any plug used with the system must be at least equal
to the current capacity of the associated receptacle.

240VAC Receptacles

One 15 amp, 240VAC duplex receptacle provides 240
VAC for auxiliary power.

One 240V (European IEC-309) 15 amp receptacle. IP44
rated.

One 240V (15-50R) 3 phase 50 amp NEMA style
receptacle.

Circuit Breakers

2 pole 15 amp rated provides overload protection for
the 240VAC (European IEC-309) receptacle and the
240VAC duplex receptacle.

2 Single pole 20 amp rated circuit breakers provides
overload protection for the 120VAC (5-20R NEMA)
duplex receptacle.

Single pole 15 amp rated provides overload protection
for the 120VAC (European IEC-309) receptacle.

3 pole, 50 amp circuit breaker provides overload pro-
tection to 240V, 3 phase and 120/240 1 phase NEMA
(15-50R and 14-50R) plugs.

RESIDUAL CURRENT DEVICE

The SAE-400

®

is configured with a Residual Current

Device (RCD) to protect all receptacles against current
leakage (eg. to ground) from all receptacles.

GROUND STUD

Provides a connection point for connecting the
machine to earth ground. For the safest grounding pro-
cedure refer to “Machine Grounding” in the INSTALLA-
TION section of this manual.

SAE-400

®