OPERATION

B-27

POWER WAVE

®

C300

• The

Power

Wave

®

C300 is now configured and

ready to weld in the synergic mode.

• Adjustment of the SPD value from the set value

has the affect of adjusting trim or arc length.

• To increase the arc length; increase the SPD

value at the Power Wave

®

C300 to a value

higher than the actual WFS.

Remember; do not change the WFS at the spool
gun.

• To decrease the arc length; decrease the SPD

value at the Power Wave

®

C300 to a value lower

than the actual WFS.

Remember: The dialed in SPD value at the Power
Wave

®

C300 does not control the WFS at the spool

gun. Rather, it is adjusting the Power Wave

®

C300

synergic work point. Therefore, adjusting the SPD
value will not change your actual WFS at the spool
gun. WFS can only be changed at the spool gun.

PUSH / PULL OPERATION

• Set the idle roll pressure on the wire drive between

an indicator reading of 0-2. A recommended start
point is 1.5.

• Configure the machine for push/pull operation

(see

parameter P.17 in the Set-up Menu section).

• Depending on the weld mode, set the Voltage or

Trim at the Power Wave

®

C300 using the right con-

trol knob located on the upper case front panel.

• The Wire Feed Speed (WFS) is set using the control

knob on the Torch. The left control knob on the
Power Wave

®

C300 is inactive. The actual WFS

being set at the torch is displayed on the Power
Wave

®

C300.

• All weld parameters normally available for the active

weld mode are available during push-pull operation.
Refer to the Operation Section of this manual.