Operation, B-19 – Lincoln Electric IM10040 POWER WAVE C300 User Manual
Page 40
B-19
OPERATION
B-19
POWER WAVE
®
C300
If the passcode does not equal zero (0000), enter the
passcode now. If the passcode has been forgotten, a
p.c. computer application or Palm O.S. application is
required to change the passcode.
If the passcode has been set to zero (0000), SETUP will
illuminate on the MSP4 panel and the display will show
the following:
Four items show on the MSP4 panel.
• Memory Value
• High Limit
• Low Limit
• Parameter Name
One of these items will flash to indicate which item will
change when the MSP4 encoder is rotated. Press the
right button on the MSP4 panel to select the item to
change.
The Limits Setup menu shows a list of all parameters
available for the weld mode stored in the memory
chosen. For example, if limits are being set for a stick
(SMAW) mode, parameters such as Run-in WFS and
Postflow will not appear.
To lock a parameter to a specific value that can-
not be changed, set the high and low limits to the
same value.
START OPTIONS
END OPTIONS
SETUP
WELD WFS
HI = 200 LO = 180
200
WELD MODE
UltimArc™ Control
START OPTIONS
END OPTIONS
SETUP
WELD WFS
HI = 200 LO = 180
200
WELD MODE
UltimArc™ Control
Memory Value
Parameter Name
Low Limit
High Limit
The memory value must always be less than or equal
to the high limit, and greater than or equal to the low
limit.
After setting limits, press the memory button with the
flashing LED. The MSP4 will ask to save or discard
the limit changes just made. Press the left MSP4 for
button (YES) to save and enable the limits and exit.
Press the right MSP4 button (NO) to exit and leave
limits unchanged.
Enabling/Disabling Limits
Limits for each memory may be enabled or disabled
by pressing and hold the appropriate memory button
for 10 seconds. Release the memory button when the
MSP4 display shows the following:
If the passcode does not equal zero, enter the passcode
now. If the passcode is zero (0000), SETUP will light
and the MSP4 displays the following:
Press the left MSP4 button (YES) to enable limits or
the right MSP4 button (NO) to disable limits. Disabling
limits does not change any limits values that may
have been previously set.
Enable/Disable
Limits: Press
10 seconds
Rotate to
Change
Value.
Press to
select item
to change.
START OPTIONS
END OPTIONS
SETUP
WELD MODE
UltimArc™ Control
ENABLE / DISABLE
MEMORY 2 LIMITS
START OPTIONS
END OPTIONS
SETUP
WELD MODE
UltimArc™ Control
Yes No
ENABLE LIMITS?