beautypg.com

Troubleshooting, Caution – Lincoln Electric IM10098 CRUISER User Manual

Page 50

background image

E-3

TROUBLESHOOTING

E-3

CRUISER™

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

When the welding arc is activated,
the drive rolls spin but no arc is pre-
sent.

The arc goes to full output.

The Cruiser welds for a short peri-
od, then the arc goes out, the wire
stops, travel continues, and no
error codes are displayed on the
pendant.

1. Check all electrode and work

connections.

1. Check for loose or damaged

work and electrode sense leads.

1. Verify work sense lead is making

a good connection and there is
no damage to the lead.

2. Check the electrode sense lead

at the Cruiser and make sure it is
a good connection.

The wire drive feeds wire in the
wrong direction.

The wire drive speed is incorrect.

1.

Change P19 wire feed direction
parameter in the Set-Up menu.

1.

Verify the gear ratio of the wire
drive and P18 match.