PARAMETER

DEFINITION

P.14

Reset Consumable Weight
This parameter only appears with systems using Production Monitoring.
Use this parameter to reset the initial weight of the consumable package.

P.15

Cold-Inch Touch Sense Option
Enabled = touch sense is active when inching wire forward.
Disabled = touch sense is inactive when inching wire forward. (default)

P.21

Shutdown 2 Function Select
This option allows selection of the Shutdown 2 input function on the control
box.
Normal Shutdown = The Shutdown 2 input functions as a standard shut-
down input that locks out all input buttons (default)
Output Disable = The Shutdown 2 input functions as a machine output
lockout to disable the welding circuit but still allow cold feeding of the wire.

P.23

Trigger Fan-Out
For Sub-Arc Lead Arc machines only. Allows the Lead Arc User Interface
to control all machine triggers in a multi-arc system.
No = Only the machine connected to the User Interface can be triggered on
and off (default).
Yes = All machines in the system can be triggered on and off simultane-
ously.

P.18

Wire Drive Gear Ratio.
Set this parameter to match the gear ratio of the wire drive.
142:1 (default)
95:1
57:1

P.19

Wire Drive Direction
The feed plate of the wire drive is reversible and the wire straightener and
the nozzle assembly may be swapped. The feed plate can feed from A
(inlet ) to B (outlet); or B (inlet) to A (outlet).
Set this parameter to match the “Forward” direction of wire feeding.
A

B (Default)

B

A

P.80

Sense from Studs.
Use this parameter for diagnostic purposes only. When power is cycled,
P.80 is automatically reset to False.
False = Sensing for the electrode (67) and work (21) is determined by the
DIP switches of the system.
True = Sensing for the electrode (67) and work (21) is measured at the
studs of the power source and the DIP switch settings are overridden.

P.99

Show Test Modes
Many weld tables include special modes for testing and servicing the weld-
ing system. Set this parameter to YES to show all test modes.
When the power source is turned off, the Show Test Modes parameter
automatically reverts back to “NO”.