Command list – IEI Integration AUPS UART Protocal SPC User Manual
Page 5

AUPS
IEI Technology Corp.
- 5 -
Command List
You can use following pre-defined commands un the application to communicate with
MCU and to receive data returned from MCU.
Command List:
Command
Description
Return bytes
0x01
Select Smart Battery A
None
0x02
Select Smart Battery B
None
0x22
Read Smart Battery Type ( LION: 4C and NIMH: 4E )
1 byte
0x09
Read Smart Battery Output Voltage ( mV )
2byte
0x0A
Read Smart Battery Electric Current ( mA )
2byte
0x08
Read Smart Battery Internal Temperature ( ºC )
2byte
0x0F
Read Smart Battery Capacity ( % )
2byte
0x11
Read Smart Battery Discharging Time ( Minute )
2byte
0x40
Read Smart Battery Status 1
2byte
0x41
Read Smart Battery Status 2
2byte
0x42
Read MCU Firmware Version
1byte
0x43
Enable Buzzer
None
0x44
Disable Buzzer
None
0x45
Turn On UPS Output
None
0x46
Turn Off UPS Output
None
0x47
Enable LAN
None
0x48
Disable LAN
None
0x50
Read IP Address
4byte
0x51
Write IP Address
4byte
0x52
Read Gateway
4byte
0x53
Write Gateway
4byte
0x54
Read Primary DNS
4byte
0x55
Write Primary DNS
4byte
0x56
Read Secondary DNS
4byte
0x57
Write Secondary DNS
4 bytes