Example – IEI Integration AUPS UART Protocal SPC User Manual
Page 10
AUPS
IEI Technology Corp.
- 10 -
Example
AP SEND MCU RAED Voltage Command:
AP->MCU
:
Command:<02><01><09><0C><0D>
STX:0x02 Length:0x01
Command:0x09 CR:0x0D
Checksum:
(0x02+0x01+0x09)MOD 0x100 = 0x0C
MCU Response AP Voltage Value:
MCU->AP
:
Response:<02><03><09><3E><80>
STX:0x02 Length:0x03 Command:0x09 Data:0x3E80 CR:0x0D
Checksum:
(0x02+0x03+0x09+0x3E+0x80)MOD 0x100 = 0Xcc
Return Value:0x3E80(16000mV)
AP SEND MCU RAED IP Address Command:
AP->MCU
:
Command:<02><01><50><53><0D>
STX:0x02 Length:0x01
Command:0x50 CR:0x0D
Checksum:
(0x02+0x01+0x50)MOD 0x100 = 0x53
MCU Response AP IP Address:
MCU->AP
:
Response:<02><05><50>
STX:0x02 Length:0x05
Command:0x50 Data1:0xA9
Data2:0xFE Data3: 0x01 Data4 :0x01
CR:0x0D
Checksum:
(0x02+0x05+0x50+0xA9+0xFE+0x01+0x01)MOD 0x100 = 0x00
Return IP Address: A9: FE: 01: 01
AP SEND MCU Write IP Address Command:
AP->MCU
:
Command+ data:<02><05><51>
STX:0x02
Length:0x05
Command:0x51 Data1:0xA9
Data2:0xFE Data3: 0x01 Data4 :0x01 CR:0x0D
Checksum:
(0x02+0x05+0x51+ 0xA9+0xFE+ 0x01+ 0x01)MOD 0x100=0x01
Notes: A
ngle brackets < > : indicate data in hex value.