Tb-2 – Warner Electric CBC-300C Dual User Manual
Page 9
![background image](/manuals/354742/9/background.png)
9
Warner Electric • 800-825-9050
P-269-1
CBC-300-2
External Level Adjustment with Internal
Current Limit Adjust
q 1. Wire the external level adjustment
potentiometer on Terminal Block TB-2 as
shown in the diagram. (See Figure 5)
q 2. If the optional accessory potentiometer kit
is used, wire the potentiometer per the colors
as shown in the diagram.
q 3. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull loose from the terminals.
Note: The level adjustment controls both the
Channel 1 and Channel 2 outputs from 0
maximum as set by the current limit adjust
potentiometers.
q 4. After the pot(s) have been wired to the
appropriate terminal block(s), mount the PCB
and bracket assembly and reattach to the
chassis with the four screws removed in step
2 above.
q 5. For the CBC-300-2 reattach the internal
potentiometer knobs.
q 6. Double check all wiring connections for the
potentiometer(s) and the main terminal block
to insure proper connections.
CBC-300-3
External Current Limit and Level Adjust
q 1. Wire the external current limit adjust
potentiometer to Terminal Block TB-3 for
Channel 1 and Terminal Block TB-4 for
Channel 2 as shown in the diagram. (See
Figures 6 & 7)
q 2. If the optional accessory potentiometer kits
are used, wire per the color codes as shown
in the diagram.
q 3. Make sure all terminals are securely
fastened and the wiring cables are secured
so that it can’t pull loose from the terminals.
q 4. Wire the external level adjust potentiometer
to Terminal Block TB-2 as shown in the
diagram. (See Figure 5)
q 5. If the accessory potentiometer kit is used,
wire per the color codes as shown in the
diagram.
q 6. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull loose from the terminals.
Note: The level adjustment controls both
Channel 1 and Channel 2 outputs from 0
maximum level as set by the current limit adjust-
ment potentiometers.
CBC-300-2, CBC-300-2C
External Level Adjust w/Internal
Current Limit Adjust
RED
BLK
CW
5K POT
10 FT MAX
LEVEL
1
TB2
2
TB-2
(Figure 5)