Warner Electric CBC-300C Dual User Manual
Page 7
7
Warner Electric • 800-825-9050
P-269-1
Clutch – Electrically Released Brake Wiring
(Power on clutch / power off Brake)
(Figure 4)
q 1. Connect the Brake to Terminals 4 and 5.
Observe the polarity when making
connections. Tighten Terminal 4 securely.
q 2. Connect the Clutch to Terminals 7 and 8.
Tighten Terminal 7 securely.
q 3. Connect the switching for Channel 1 to
Terminals 5 and 6. Tighten terminals securely.
q 4. Connect the switching for Channel 2 to
Terminals 8 and 9. Tighten terminals securely.
q 5. Set DIP Switch, SW1 for proper current
setting before applying power to the control.
See Internal Switch Settings Chart for proper
DIP Switch settings.
q 6. If external potentiometers are being used,
then proceed to the external potentiometer
wiring section. If they are not used, this
completes the wiring of the control.
q 7. Double check all connections before
applying power.
4
5
6
7
8
9
2
3
1
2
3
1
1.5A
FUSE
or
G
H
N
120 VAC
G
H
N
120 VAC
Clutch
Brake
Channel 1
Channel 2
+
-
+
-
ER
External switching by
customer,
see
specification.
Note: If Solid-state NPN switching
is used, emitter is connected to
terminal 6 or 9 and collector is
connected to terminal 5 or 8.
Note: Electrically released
brake must be connected to
Channel 1 Output when
CBC-200 is used.