background image

15 —

Power
Input Voltage

12 to 48 VDC, redundant inputs

Input Current @ 24VDC

0.25 A (EDS-305, EDS-305-M, EDS-305-S, EDS-308)

0.35 A (EDS-308-M, EDS-308-S, EDS-308-MM, EDS-308-SS)

Connection

Removable Terminal Block

Overload Current Protection

1.1 A (EDS-305, EDS-305-M, EDS-305-S, EDS-308) 1.6 A
(EDS-308-M, EDS-308-S, EDS-308-MM, EDS-308-SS)

Reverse Polarity Protection

Present

Mechanical
Casing

IP30 protection, aluminum case

Dimensions

53.6 x 135 x 105 mm (W x H x D)

Weight

0.63 kg

Installation DIN-Rail,

Wall

Mounting

Environmental
Operating Temperature

0 to 60oC (32 to 140oF)
-40 to 75oC (-40 to 167oF), for “-T” models

Storage Temperature

-40 to 85oC (-40 to 185oF)

Ambient Relative Humidity

5 to 95% (non-condensing)

Regulatory Approvals

Safety

UL60950, UL 508, CSA C22.2 No. 60950, EN60950

Hazardous Location

UL/cUL Class I, Division 2, Groups A, B, C and D
ATEX Class I, Zone 2, EEx nC IIC

EMI

FCC Part 15, CISPR (EN55022) class A

EMS

EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3

Shock IEC

60068-2-27

Free Fall

IEC 60068-2-32

Vibration IEC

60068-2-6

WARRANTY