Power Supply:

3V DC; two “C" cell Alkaline batteries

Maximum Sensitivity:

Per SAE J1627 Rating Criteria

Certified @ 0.5 oz/yr. (14gr/yr)

Ultimate sensitivity

TIFXL-1A

less than 0.4 oz/yr (11 gr/yr) for all

Halogen based refrigerants.

TIFRX-1A

less than 0.25 oz/yr (7 gr/yr) for all

Halogen based refrigerants.

Sensing Tip Life:

Approximately 20 hours

Operating Temperature:

30° -125° F (0° to 52° C)

Battery Life:

TIFXL-1:

Approximately 40 hours normal use

TIFRX-1A:

Approximately 30 hours normal use

Duty Cycle:

Continuous, no limitation

Response Time:

Instantaneous

Reset Time:

One second

Warm-Up Time:

Approximately 2 Seconds

Unit Weight:

1.2 pounds (560 grams) (with batteries)

Unit Dimensions:

9" x 2.5" x 2.5"

(22.9cm x 6.5cm x 6.5cm)

Probe Cord Length:

14" or 35.5 cm

This instrument has been designed and manufactured to provide unlimited service.

Should the unit be inoperative, after performing the recommended maintenance, a

no-charge repair or replacement will be made to the original purchaser if the claim is

made within TWO years from the date of purchase. This warranty applies to all

repairable instruments that have not been tampered with or damaged through

improper use. This warranty does not cover batteries, sensing tips, tip protectors, or

any other materials that wear out during normal operation of the instrument.

Before returning your instrument for repair please make sure that you have carefully

reviewed the Unit Maintenance section of this manual to determine if the problem

can be easily repaired. Make sure that you have either replaced or cleaned the

sensing tip and tip protector and that the batteries are working properly BEFORE

returning the unit. If the instrument still fails to work properly please call the

Customer Service Department for an RMA number (800) 327-5060. Pack the instru-

ment and send the unit to the repair facility address on the back cover of this manu-

al. Repaired or replaced tools will carry an additional 90 day warranty. For more

information please call (800) 327-5060.