Operator’s Manual

923064-00 Rev A

7

Electrical Ratings

Maximum Input Voltage

1000 V rms (1400 V DC + peak AC)

Installation (Overvoltage) Category

III

Pollution Degree

2

Measurement Category III (CAT III) is applicable for measurements performed in the building installation.
Pollution Degree 2 is applicable to an operating environment where normally only dry non-conductive pollution
occurs. Occasionally a temporary conductivity caused by condensation must be expected.

General Characteristics

Operating Temperature

-10º C to 40º C

Storage Temperature

-30º C to 70º C

Altitude, Operating

up to 2000 m (6560 ft)

Cable Length

1.3 m

Weight (probe only)

42 g

Power requirement

Four internal 1.5 V AA size batteries or

6 V d.c. / 60 mA mains adaptor

(Not supplied )

Dimensions

6.6" (168 mm) x 2.4" (62 mm) x 0.79" (20 mm)

(excluding casing )

Cables

BNC, 95 cm ( RG58 / U ), Input Lines: 45 cm

(PVC, double insulation )

Accessories

2 x Safety Hooks, 4 mm compatible (1 red, 1 black)

Weight

9.35 oz ( 285 g ) excluding batteries

and casing

Safety Certification

EN61010-1:2010 ; EN61010-031/A1:2008

1000V CAT III Approval