beautypg.com

Diagnostics – parking light flash table, Installation guide, P. 31 – Autostart AS-2775 User Manual

Page 31

background image

Installation Guide

P. 31

Diagnostics – Parking Light Flash Table

Flashes

Description

1

• Doors locked, starter kill armed.

• Run time has expired.

TRUNK

button pressed.

• Start signal received by the module.

• Cold weather mode cancelled.

2

• Doors unlocked, starter kill disarmed.

• Remote start attempt cancelled by remote.

• Exiting ignition valet.

• Exiting remote valet.

• Power-up reset.

• Board set from manual to automatic; power

ON.

• Power ON to OFF (automatic transmission).

2 slow flashes then

8 quick flashes

• Reset from Manual to Automatic

3

• Entering cold weather mode.

• Extended run time.

• Entering ignition valet.

• Entering remote valet.

3 Slow

(automatic transm.)

• Parking brake is engaged

• Yellow loop has been reconnected

4

• +12 V detected on the brake input wire either while cranking or during run time.

• Entering multi-speed tach programming.

• Entering time delay adjustment in virtual tach system

• Board set from automatic to manual; power ON.

• Power ON to OFF (manual transmission).

5 Fast

• Tach signal programmed.

• New transmitter programmed

6

• A remote start was attempted while a tach-before-crank signal was detected before cranking.

8

• Unit reset; see “Resetting the Module”.

10

• A ground (-) signal was detected on the hood pin input wire.

1 – pause – 2

• There was a remote start attempt while the vehicle was in valet mode.

• Failed start: vehicle’s low battery voltage.

ON SOLID for 3

seconds….

…followed by 1 flash

Exiting cold weather mode

…followed by 3 flashes

Entering cold weather mode

ON continuously

Idle mode: Idle mode is engaged

Run time: The vehicle has been remote started and is in run time.

ON 2 seconds

• The hood has been opened and a ground (-) signal has been detected on the hood pin input

wire.

ON 4 seconds

• Locking or unlocking a door (with Door pulses configured to 4 sec.)

ON 20 seconds

• The hood pin has been flashed and you are now in the programming centre.

Continuous flashes

25 seconds

• Panic mode is activated.

Continuous flashes

60 seconds

• OEM alarm triggered (Honk)