Maintenance, Operation and maintenance – LiftMaster LA400 Residential DC Linear Gate Operator User Manual
Page 41

40
OPERATION AND MAINTENANCE
» MAINTENANCE
MAINTENANCE
NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• Inspection and service should always be performed anytime a malfunction is
observed or suspected.
• When servicing, please do some “house cleaning” of the operator and the area
around the operator. Pick up any debris in the area. Clean the operator as
needed.
• It is suggested that while at the site voltage readings be taken at the operator.
Using a Digital Voltmeter, verify that the incoming voltage to the operator it is
within ten percent of the operator’s rating.
• See page 33 for instructions on how to adjust the gate force.
CHECK AT LEAST ONCE EVERY
DESCRIPTION
TASK
MONTH
6 MONTHS
3 YEARS
External Entrapment Protection System
Check and test for proper operation
X
Manual Release
Check and test for proper operation
X
Gate
Inspect for wear or damage
X
Accessories
Check all for proper operation
X
Electrical
Inspect all wire connections
X
Mounting Hardware
Check for tightness
X
Batteries
Replace
X
Operator
Inspect for wear or damage
X
Warning Signs
Make sure they are present
X
Disconnect power before servicing.