19

SPEEDMASTER™ OPERATION MANUAL

Operation

174103

Manual Operation

1. Set the Signal/Manual Switch located on the enclosure to the

MANUAL position.

2. Set the speed adjust dial to “0” (full CCW).
3. Apply AC line voltage
4. Set the POWER switch to the ON position
5. Slowly advance the speed adjust dial CW. The motor slowly

accelerates as the dial is tunred CW. Continue until the
desired speed is reached.

6. To coast the motor to a stop, turn the speed adjust dial to “0” or

set the POWER switch to the OFF position.

Signal Operation

1. Set the Signal/Manual Switch located on the enclosure to the

SIGNAL position.

2. Apply AC line volage.
3. Set the POWER switch to the ON position
4. Apply minimum current or voltage signal. Adjust the SIG MIN

trimpot to achieve the desired minimum motor speed.

5. Apply the maximum current or voltage signal. Adjust the SIG

MAX trimpot to achieve the desired maximum motor speed.